TSC CO.,LTD
japanese
REAL GUARD REAL COAT COMPANY CONTACT
REAL GUARD
REAL GUARD
Nov2002
Japan Highway Hokuriku Branch Maintenance Division
Test Application Plan
- Construction Method of Surface Coating / Modification for Concrete Structures -
The Purpose of Test Application:
In recent years, there have been advancements in surface coating and surface modification technology for concrete structures. And, based on the results attained from concrete coating material test that was done by JH Testing Laboratory last year, the purpose of this test application plan is to confirm the applicability and endurance of typical surface coating / modification material at actual construction sites.
TOP
The Outline of Test Application:
(1) Test Material
Table 1: Subject material for test application
Construction Method Manufacturer Main Ingredient
Material Code Name Code Name
Surface Modification Material EF-1 Hi-Bond ND2000F DD Daido Paint Epoxy with fluorine
EF-1 Resi-Guard #200PB DN Dai Nippon Paint Poly Chlorine Rubber with fluorine
Surface Modification Material RG-1 Real Guard (type A) TS TSC Alkyl-alkoxy-silan-monomer
* The above materials were selected by our JH head office


(2) Test Construction Sites (Bridges)
Highway Name Section Bridge Name Office in Charge
Hokuriku Route Mikawa-Kanazawa West Yamashimagawa Bridge Kanazawa Office
Hokuriku Route Oyashirazu-Itoigawa Shin-Omigawa Bridge Johetsu Office
Table 2: Subject concrete structures for test application
Bridge Name Yamashimagawa Bridge Shin-Omigawa Bridge
Structural Format Simple Platter Mid Air Floorboard RC Continuous Mid Air Floorboard
PC Simple Mid Air Floorboard
PC Continuous Mid Air Floorboard
PC Continuous Box
Total Area 250 u 345.6 u
Deterioration Environment Salt Deterioration Environment Sea Level (m) 70m 600m
Salt Level at Reinforcing Bar (kg/u) 5.5 kg/u 0.30 kg/u
Weather Endurance Influence of UV Northeast side East-West Axis
Load Wear Out Influence of cars None None
Influence of Water from back side of structure Yes None
Current Situation of Structure No cracks Unknown
Comments High salt level at reinforcing bar and less cracks on surface of concrete indicates being in the initial stage of deterioration Low salt level indicates that the environment is less likely to cause any salt damages to the structure. Also, sea level of 600m indicates that salt composites are less likely to fly up and damage the structure
TOP
REAL GUARD
REAL GUARD
Composition: For both A and B type
Application Specification
Analysis Report for REAL GUARD A
Result Analysis based on the Standard of Water Supply Regulation
Test Method and Its Lowest Result in Fixed Quantity of Water
Selected Portfolio
Msds